A more precise, repeatable and diagnostic alternative to surface electromyography: an appraisal of the clinical utility of acoustic myography

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Standard

A more precise, repeatable and diagnostic alternative to surface electromyography : an appraisal of the clinical utility of acoustic myography. / Harrison, Adrian P.

I: Clinical Physiology and Functional Imaging, Bind 38, Nr. 2, 2018.

Publikation: Bidrag til tidsskriftTidsskriftartikelForskningfagfællebedømt

Harvard

Harrison, AP 2018, 'A more precise, repeatable and diagnostic alternative to surface electromyography: an appraisal of the clinical utility of acoustic myography', Clinical Physiology and Functional Imaging, bind 38, nr. 2. https://doi.org/10.1111/cpf.12417

APA

Harrison, A. P. (2018). A more precise, repeatable and diagnostic alternative to surface electromyography: an appraisal of the clinical utility of acoustic myography. Clinical Physiology and Functional Imaging, 38(2). https://doi.org/10.1111/cpf.12417

Vancouver

Harrison AP. A more precise, repeatable and diagnostic alternative to surface electromyography: an appraisal of the clinical utility of acoustic myography. Clinical Physiology and Functional Imaging. 2018;38(2). https://doi.org/10.1111/cpf.12417

Author

Harrison, Adrian P. / A more precise, repeatable and diagnostic alternative to surface electromyography : an appraisal of the clinical utility of acoustic myography. I: Clinical Physiology and Functional Imaging. 2018 ; Bind 38, Nr. 2.

Bibtex

@article{abfa252c39c84f8a851e73959379c859,
title = "A more precise, repeatable and diagnostic alternative to surface electromyography: an appraisal of the clinical utility of acoustic myography",
abstract = "Acoustic myography (AMG) enables a detailed and accurate measurement of those muscles involved in a particular movement and is independent of electrical signals between the nerve and muscle, measuring solely muscle contractions, unlike surface electromyography (sEMG). With modern amplifiers and digital sound recording systems, measurements during physical activity both inside and outside a laboratory setting are now possible and accurate. Muscle sound gives a representation of the work of each muscle group during a complex movement, and under certain forms of movement even reveals both concentric and eccentric activity, something that sEMG is incapable of. Recent findings suggest that AMG has a number of advantages over sEMG, being simple to use, accurate and repeatable as well as being intuitive to interpret. The AMG signal comprises three physiological parameters, namely efficiency/coordination (E-score), spatial summation (S-score) and temporal summation (T-score). It is concluded that modern AMG units have the potential to accurately assess patients with neuromuscular and musculoskeletal complaints in hospital clinics, home monitoring situations as well as sports settings.",
author = "Harrison, {Adrian P}",
note = "{\textcopyright} 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.",
year = "2018",
doi = "10.1111/cpf.12417",
language = "English",
volume = "38",
journal = "Clinical Physiology and Functional Imaging",
issn = "1475-0961",
publisher = "Wiley-Blackwell",
number = "2",

}

RIS

TY - JOUR

T1 - A more precise, repeatable and diagnostic alternative to surface electromyography

T2 - an appraisal of the clinical utility of acoustic myography

AU - Harrison, Adrian P

N1 - © 2017 Scandinavian Society of Clinical Physiology and Nuclear Medicine. Published by John Wiley & Sons Ltd.

PY - 2018

Y1 - 2018

N2 - Acoustic myography (AMG) enables a detailed and accurate measurement of those muscles involved in a particular movement and is independent of electrical signals between the nerve and muscle, measuring solely muscle contractions, unlike surface electromyography (sEMG). With modern amplifiers and digital sound recording systems, measurements during physical activity both inside and outside a laboratory setting are now possible and accurate. Muscle sound gives a representation of the work of each muscle group during a complex movement, and under certain forms of movement even reveals both concentric and eccentric activity, something that sEMG is incapable of. Recent findings suggest that AMG has a number of advantages over sEMG, being simple to use, accurate and repeatable as well as being intuitive to interpret. The AMG signal comprises three physiological parameters, namely efficiency/coordination (E-score), spatial summation (S-score) and temporal summation (T-score). It is concluded that modern AMG units have the potential to accurately assess patients with neuromuscular and musculoskeletal complaints in hospital clinics, home monitoring situations as well as sports settings.

AB - Acoustic myography (AMG) enables a detailed and accurate measurement of those muscles involved in a particular movement and is independent of electrical signals between the nerve and muscle, measuring solely muscle contractions, unlike surface electromyography (sEMG). With modern amplifiers and digital sound recording systems, measurements during physical activity both inside and outside a laboratory setting are now possible and accurate. Muscle sound gives a representation of the work of each muscle group during a complex movement, and under certain forms of movement even reveals both concentric and eccentric activity, something that sEMG is incapable of. Recent findings suggest that AMG has a number of advantages over sEMG, being simple to use, accurate and repeatable as well as being intuitive to interpret. The AMG signal comprises three physiological parameters, namely efficiency/coordination (E-score), spatial summation (S-score) and temporal summation (T-score). It is concluded that modern AMG units have the potential to accurately assess patients with neuromuscular and musculoskeletal complaints in hospital clinics, home monitoring situations as well as sports settings.

U2 - 10.1111/cpf.12417

DO - 10.1111/cpf.12417

M3 - Journal article

C2 - 28251802

VL - 38

JO - Clinical Physiology and Functional Imaging

JF - Clinical Physiology and Functional Imaging

SN - 1475-0961

IS - 2

ER -

ID: 177291741